Skip to main content

Table 3 Computation results for four different full-order FD filter cases

From: Fault detection reduced-order filter design for discrete-time Markov jump system with deficient transition information

Transition rate matrix

J min

Time steps

Completely known (case 1)

2.0032

104

Polytopic uncertain (case 2)

2.4527

106

Partly known (case 3)

2.5062

107

Completely unknown (case 4)

3.2015

109